Panoli Fire Review and Used Oil Processing Hazards

 HSE-RM SOLUTIONS | Technical review | 4 November 2026

 


The fire reported at Supreme Petrochem in Panoli raises a practical question for used-oil processing facilities: what sequence could bring a combustible release, air and an ignition source together, and which controls should interrupt that sequence?

Investigators need to establish the material involved, the operating stage, the first release or abnormal condition, the ignition source and the reasons the event escalated. The scenarios below are an investigation framework for this type of processing industry, not findings about Supreme Petrochem.

The incident and the industry

Sandesh reports a fire and blasts at Supreme Petrochem, Panoli GIDC, with three workers seriously burnt. It reports attendance by the Directorate of Industrial Safety and Health, Gujarat Pollution Control Board and police, while stating that an official cause had not been established. An agency attending the scene is not equivalent to an agency issuing a cause determination.

A historical GPCB list of actual users, dated 31 March 2024 and available through a third-party document archive, identifies Supreme Petrochem, GPCB ID 78567, Plot C1-B 1708, GIDC Panoli, against used oil. The June 2023 list records a capacity of 2,160 tonnes per year. This supports a used-oil processing or recycling connection. These records do not establish the present equipment, exact process, current authorisation status or equipment involved in the fire.

Comparable operations in Gujarat

The following examples identify the broader sector. Historical listing does not establish that a facility remains operational or uses the same process as Supreme Petrochem.

Facility

Gujarat location

Evidence of comparable activity

ABC Organics & Chemicals

Panoli, Bharuch

Used oil in the March 2024 GPCB list

Royal Petro Oil Refinery LLP

Gandhidham, Kutch

Used oil in the same list

Classic Oil Refinery

Choryasi, Surat

Used oil in the same list

Greenspace Enviro Services

Anand district

Its own website describes used/waste-oil re-refining using thin-film evaporation, producing base oil and light oil

Sources: GPCB List (https://legalupdate.qhsealert.com/file/202_Actual%20users%20for%20Used%20Oil%20%26%20Waste%20Oil.pdf)

 

These are examples of related operations, not allegations of unsafe conditions. A sector review should group facilities by their actual feedstock, heating method, distillation technology, inventories and safeguards.

 

How the process can create fire hazards

A representative re-refining route includes receipt and storage, solids removal, dehydration, removal of lighter fuel fractions, distillation, condensation, product collection and finishing. Vacuum or wiped-film equipment is used in some processes. Other recovery plants have different arrangements. (Source: https://chemsept.in/Views/Projects/UsedOilRefining.aspx)

 

Used oil is a variable feedstock. Water, particles and chemicals can enter it during service or collection. Its hazards cannot be assessed solely from the original lubricant specification.

 

Vapour generation is expected during distillation. An explanation such as “gas formed” must establish whether this was normal evaporation, unexpected volatile contamination, steam generation or decomposition. It must then explain the release, pressure conditions and ignition.

 

Fuel and oxidiser identification

Material or condition

Where to look

Why it matters

Used oil with lighter fuel or solvent contamination

Incoming tankers, drums, feed tanks and mixed batches

Volatility and ignition behaviour may differ from the expected feed

Light hydrocarbon fractions

Defueling equipment, condensers and receivers

A release can create an ignitable vapour mixture

Heated oil and oil mist

Pumps, flanges, hoses, seals and pressurised lines

Leakage can supply a pool fire or dispersed combustible spray

Heating-system fuel or thermal fluid

Burner fuel trains and hot-oil circuits, where installed

The heating utility can supply the first fuel release

Oily residues and contaminated materials

Still bottoms, sludge, insulation, filters and rags

They can contribute to fire growth; some deposits require assessment for self-heating

Air entering process equipment

Vacuum leaks, open connections and maintenance openings

Oxygen can enable combustion where combustible vapour is present

 

Oil-mist hazards need separate consideration from bulk-liquid flash point. Air is the oxidiser in these scenarios, not the fuel.

 

Hazard identification across the facility

This screening register must be developed against the site's equipment and operating limits. It is neither exhaustive nor a probability ranking.


Area and deviation

Credible mechanism to examine

Controls to assess

Feed receipt and mixing

Unexpected volatile or incompatible contamination changes the batch hazard

Traceable receipts, defined acceptance criteria, representative testing and segregation of uncertain material

Wet feed entering a hot process

Rapid vaporisation causes foaming, carryover, ejection or pressure rise

Water assessment, controlled dehydration and charging, appropriate operating limits and pressure protection

Excess heat or low inventory

Local overheating, exposed heated surfaces or degradation of susceptible material

Temperature and level protection; circulation monitoring where applicable; limits based on feed and residue properties

Vacuum failure or air ingress

Operating conditions change; an ignitable mixture may develop

Leak integrity, pressure monitoring, defined shutdown response and engineered inerting where justified

Condenser or cooling failure

Vapour is not adequately condensed and reaches unintended locations

Cooling performance monitoring, suitable trips and safe handling of uncondensed vapour

Restricted vapour or relief path

Pressure rises because generation exceeds discharge capacity

Verified relief basis, blockage inspection, controlled valve positions and safe discharge arrangements

Receiver overfill or open collection

Liquid or vapour escapes near people or ignition sources

Closed collection, suitable level protection, controlled transfer and ventilation

Pump, flange or hose leakage

Hot oil or light fractions contact an ignition source

Mechanical integrity, compatible components, leak detection and accessible emergency isolation

Heater or thermal-fluid fault

Fuel or hot fluid leaks; abnormal combustion or overheating occurs

Appropriate burner safeguards, fuel isolation and circulation/temperature protection

Maintenance during operation

Hot work, opening equipment or temporary wiring introduces ignition or releases material

Isolation, permits, atmosphere testing, contractor supervision and coordination of simultaneous work

Storage and drainage

A local release spreads through drains or exposes adjacent inventories

Compatible segregation, containment, drain control, access and emergency planning

Startup, shutdown or modification

Valve alignment, utilities or controls differ from normal operating assumptions

Specific procedures, change review, readiness checks and competent shift handover

 

The register combines process, equipment and activity scenarios. Heating or vacuum loss does not automatically cause decomposition; that depends on the material and conditions. A pressure event also does not automatically establish a combustion explosion.

 

Ignition sources and the precautions they require

 

Electrical equipment and portable devices

Assess motors, switches, junction boxes, instruments, temporary cables, lamps and portable equipment against the hazardous-area classification. Equipment suitability includes its protection method, gas group, temperature class and installation condition. “Flameproof motor installed” is not a complete assessment.

 

Flames and hot surfaces

Check fired heaters, burner fronts, exhausts, exposed hot pipework and vehicle routes against credible vapour releases. A leak reaching a heater can ignite without an electrical fault. Verify separation and the conditions under which heating must stop. (Use Guide: https://www.hse.gov.uk/comah/sragtech/techmeasareaclas.htm)

 

Static discharge

Review tanker unloading, pumping, filtration, filling and sampling. Verify bonding continuity and earthing of conductive equipment, suitable hoses and transfer methods. Earthing metal equipment alone does not resolve charging of an insulating liquid, hose or container. Avoid prescribing one flow limit for every material and arrangement. (Earthing Guide: https://www.hse.gov.uk/comah/sragtech/techmeasearthing.htm)

 

Welding and other maintenance

Consider alternatives to hot work. Where it is necessary, isolate relevant equipment, assess connected and adjacent vessels, and use suitable gas testing before and during work. The permit must describe actual precautions and supervision. An empty-looking oil vessel may still contain hazardous residue or vapour.

 

Mechanical heat and contaminated insulation

Inspect bearings, alignment and abnormal vibration. Investigate oil-soaked insulation and persistent leaks, particularly around hot equipment. Replacing insulation without finding the leak can leave the underlying hazard in place.

 

Controls that function when demanded

Establish the required response to excessive temperature, low inventory, loss of circulation, cooling failure and abnormal pressure. Verify the complete protective function, including sensors, logic, final isolation devices and essential utilities. Independence, bypass management and proof testing matter. A shutdown must reach a defined safe state; some processes require cooling to continue after heating stops.

 

Evidence authorities should examine

Life safety and scene stabilization take priority. Once access is safe, preserve evidence before dismantling, cleaning or restarting equipment. Record emergency actions that changed valve positions, power supplies or equipment condition.

 

Investigation question

Evidence to seek

Where did the event begin?

CCTV, first witness observations, fire-service records, original equipment locations and competent fire-origin examination

What material was being processed?

Batch identity, receipts, supplier history, retained feed and product samples, laboratory results and tank-transfer records

What was the operating stage?

Charging, heating, dehydration, distillation, discharge, cleaning or startup records

What changed before the event?

Time-aligned temperature, level, pressure/vacuum, cooling, flow, power and alarm histories

Where did material first escape?

Seal and flange condition, pipe failures, vessel openings, receivers, drains, vent outlets and vacuum-pump discharge

What supplied ignition?

Heater operation, electrical examination, hot-work records, static-control evidence, hot surfaces and vehicle activity

Did pressure failure precede fire?

Vessel deformation, fracture assessment, relief condition, pressure history and the sequence visible in recordings

Why did protection not stop escalation?

Setpoints, response times, calibration, complete trip tests, bypass records, isolation performance and shared utility failures

Why were workers exposed?

Work positions, access routes, warning, emergency shutdown access, supervision and evacuation arrangements

What changed recently?

Feed suppliers, throughput, temperatures, piping, equipment, staffing, maintenance and operating procedures

 

Testing should be planned by competent investigators, with samples and components documented and preserved. The table is a proposed evidence plan, not a statement that these records exist at the site.

 

A burnt cable alone cannot establish that an electrical fault started the fire. A damaged vessel alone cannot establish that an explosion initiated it. Both may be consequences of an earlier event. Competing explanations should be tested against the sequence and physical evidence.

 

HSE's investigation framework distinguishes immediate events from the underlying arrangements that allowed them. The review should therefore also examine competence, maintenance, communication and how identified defects were managed.

 

Suggested coordination between authorities

Within their respective powers, a coordinated review could allocate these workstreams:

  • Fire service and forensic specialists: origin, first fuel, ignition sequence, spread and emergency-response observations.
  • DISH: process design, operating limits, machinery integrity, protective functions, work practices and management arrangements.
  • GPCB: actual feed and waste streams, approved activities and consent conditions, storage, residues, emissions and contaminated runoff.
  • Police and forensic laboratory: witness evidence, preservation and examination of relevant components and samples.
  • District and industrial-estate emergency teams: mutual aid, access, adjacent exposures, off-site consequences and communication.

 

These are suggested technical workstreams, not a substitute for each agency's statutory remit. Current approvals should be checked directly; an old list cannot establish whether a renewal was granted.

 

Actions for similar facilities

Operators can review credible hazards without assuming that the same failure occurred at Panoli. Start with feed acceptance, heating limits, condenser performance, vapour discharge routes, leak history, ignition controls and functional testing of shutdowns.

 

Where a critical safeguard cannot be demonstrated or a dangerous condition exists, have competent personnel assess whether the affected operation can continue safely. Set corrective actions and restart conditions around the actual hazard.

 

Fire protection, containment and emergency response remain necessary because preventive controls can fail. Their adequacy should reflect the inventories, release scenarios and neighbouring exposures.

 

An authority's sector advisory would be most useful if it identifies the failed mechanism, the equipment and operations to which it applies, the checks required, the acceptance criteria and responsibility for closure. Confirmed findings should be distinguished from unresolved hypotheses.

 

HSE-RM SOLUTIONS perspective

 

The useful outcome of an investigation is an explanation that leads to verifiable risk reduction.

 

For used-oil processing, that means connecting feed characteristics, process conditions, equipment integrity, operating activities and human decisions. It means establishing which safeguards were needed, whether they worked and how their effectiveness will be maintained.

 

HSE-RM SOLUTIONS can support this approach through process hazard identification, focused HAZOP studies, ignition-source reviews, equipment and protective-system assessments, and practical operating and emergency procedures.

 

Identify the hazardous sequence. Interrupt it. Verify the control.

HSE-RM SOLUTIONS
Your Partner In Safety...

NTPC North Karanpura Conveyor Collapse — Incident Investigation and Hazard Assessment